Fire Watch Officer Training Standards
Every Fire Watch Officer we dispatch completes a structured training program before their first assignment. Our curriculum is built around federal OSHA standards, Washington State WISHA rules, and the Seattle Fire Department's own fire watch guidance — so the officer standing in your building understands exactly what the authority having jurisdiction expects of them.
Fire Watch Fundamentals
- Purpose and legal basis of a fire watch, and the limits of the assignment
- Recognizing signs and conditions of fire: smoke, odor, heat, discoloration, abnormal equipment behavior
- Immediate response sequence: alert occupants, call 911, then act only within trained limits
- Safe use of portable fire extinguishers on incipient stage fires (PASS method)
- Executing the building's fire control and evacuation plan, including defend-in-place occupancies
- Patrol route planning so every affected floor, corridor, stairwell, and concealed space is covered on interval
OSHA Federal Standards
- 29 CFR 1910.36 and 1910.37 — exit route design, maintenance, and keeping means of egress unobstructed
- 29 CFR 1910.38 — emergency action plans, alarm procedures, and occupant accountability
- 29 CFR 1910.155–165 — fire protection subpart, extinguishers, and employee alarm systems
- Hazard communication and recognition of ignition sources during patrol
- Incident reporting and personal protective equipment expectations
WISHA / Washington WAC Requirements
- WAC 296-800 — Safety and Health Core Rules governing every Washington worksite
- WAC 296-24-585 — fire protection and employee alarm system requirements
- WAC 296-24-567 — portable fire extinguisher requirements and inspection expectations
- Washington-specific accident prevention program and reporting duties
- State licensing and certification requirements for security personnel performing fire watch duties
Seattle Fire Department CAM 5991
- When the Seattle Fire Department requires a fire watch and who must be notified
- Impairment reporting before and after work on alarm, sprinkler, or standpipe systems
- Required patrol intervals and continuous-coverage expectations for the duration of the impairment
- Officer duties defined by the AHJ, including immediate 911 notification and occupant warning
- Information the fire marshal expects to find in the fire watch log during inspection
Logbook Accountability
- Every pass recorded with date, time, officer name, area covered, and conditions observed
- Contemporaneous entries — logs are written during the watch, never reconstructed afterward
- Documenting deficiencies, blocked egress, and any notification made to management or 911
- Supervisor review of logs each shift and correction of gaps in coverage
- A digital copy of the fire watch log delivered to ownership and management so coverage can be verified remotely
- Retention of records for fire marshal inspection, insurance, and liability protection
Ongoing Qualification
- Background screening and Washington State security licensing verified before deployment
- Site-specific orientation covering the building's fire control plan, alarm devices, and egress routes
- Field supervision with unannounced site checks during active fire watch assignments
- Refresher training and post-assignment debriefs after every significant incident
- Documented training files available to ownership on request